Single Core Power Cable

Single Core Power Cable
Product Introduction:
Single Core Power Cable is a single core power cable to IEC 60502, with nominal voltage Uo/U ranging from 1.8/3KV to 26/35KV. It is designed for distribution of electrical power.
Send Inquiry
Description
Technical Parameters

Hebei Hualun Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of single core power cable in China. If you're going to wholesale durable single core power cable made in China, welcome to get quotation from our factory. All customized products are with high quality and competitive price.

 

Single Core Power Cable has a plain annealed copper or aluminium conductor complying with IEC 60228 class 1 or 2. It is designed for distribution of electrical power with nominal voltage 1.8/3KV to 26/35KV and frequency 50Hz. It is suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water, as well as on cable trays for industries, switchboards and power stations. Insulation is PVC for 1.8/3KV and 3.6/6KV cables, XLPE or EPR/HEPR also available.

 

 
Product Parameters

Item

Parameter

Standard

IEC 60502 Part 1 (1.8/3KV), Part 2 (3.6/6KV to 18/30KV)

Nominal voltage Uo/U

1.8/3KV to 26/35KV

Frequency

50Hz

Conductor

Plain annealed copper or aluminium complying with IEC 60228 class 1 or 2

Conductor screen

Extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation; not necessary for both PVC and EPR/HEPR insulated 1.8/3KV and 3.6/6KV cables

Insulation

PVC (1.8/3KV, 3.6/6KV), XLPE or EPR/HEPR

Armour

Round aluminium wire armour applied helically over an extruded separation sheath

Over sheath

Extruded thermoplastic compound (PVC, PE or LSZH as an option) or elastomeric compound (CSP or chlorosulfonated PE)

Over sheath thickness

Nominal thickness calculated by 0.035D+1; not less than 1.4mm for unarmoured cables and cables with over sheath not applied over armour, metallic screen or concentric conductor; not less than 1.8mm for cables with over sheath applied over armour, metallic screen or concentric conductor

 

 
Applications
  • Power supply stations
  • Indoors, cable ducts, outdoors
  • Underground, in water
  • Cable trays
  • Industries, switchboards, power stations

 

 

Performance Characteristics

 

1.Conductor is plain annealed copper or aluminium complying with IEC 60228 class 1 or 2

2.Conductor screen consists of an extruded layer of non metallic, semi-conducting compound firmly bonded to the insulation to exclude all air voids

3.Insulation is PVC for 1.8/3KV and 3.6/6KV cables, XLPE or EPR/HEPR also available

4.Armour consists of round aluminium wire armour applied helically over an extruded separation sheath

5.Over sheath comprises a layer of extruded thermoplastic compound or elastomeric compound, PVC, PE or LSZH available as an option

6.Nominal over sheath thickness calculated by 0.035D+1, with minimum thickness according to cable construction

product-711-473
product-630-417 product-939-579

 

 

Product Q&A

 

Q: What effect does the armour have when Single Core Power Cable is used in an AC system?

A: When single core cables are used in an AC system, the aluminium wire armour or metallic screen will generate induced currents, causing additional losses. Non-magnetic armour should be used, or an earthing method other than two-end earthing should be adopted for the armour, as determined by the system earthing design.

Q: How are the conductor screen and insulation screen treated at joints?

A: At joints, the conductor screen and insulation screen should be stripped back according to the accessory manufacturer's instructions. After stripping, the screen should be restored with a compatible semi-conducting material before applying the joint insulation. The stripping length and step dimensions shall follow the joint process requirements to avoid electric field concentration.

Q: What are the fixing requirements when this cable is installed on cable trays or in vertical shafts?

A: For vertical installation, cable cleats should be installed at the designed spacing. Non-magnetic material cleats should be used to avoid forming a closed magnetic circuit. For horizontal tray installation, single core cables should be arranged in a triangular formation or spaced apart as designed, to reduce induced currents and heat dissipation effects.

 

 

 

Hot Tags: single core power cable, China single core power cable manufacturers, suppliers, factory

Send Inquiry