Three Core MV Cables

Three Core MV Cables
Product Introduction:
Three Core MV Cables are three core medium voltage cables to VDE 0276, with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV, at frequency 50Hz. They are designed for distribution of electrical power.
Send Inquiry
Description
Technical Parameters

Hebei Hualun Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of three core mv cables in China. If you're going to wholesale durable three core mv cables made in China, welcome to get quotation from our factory. All customized products are with high quality and competitive price.

 

Three Core MV Cables have stranded compacted circular copper or aluminium conductors according to IEC 60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383. All internal interstices of the conductor are filled with water blocking compound to prevent ingress of water through conductor during storage, handling, installation and operation of the cable. Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1 with high degree of cross-linking, free from contaminants, air voids and heat resistant by dry cured process. The standard is DIN VDE 0276 Part 620-622, HD 620 S1. They are designed for distribution of electrical power with nominal voltage 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water, as well as on cable trays for industries, switchboards and power stations.

 

 
Product Parameters

Item

Parameter

Standard

DIN VDE 0276 Part 620-622, HD 620 S1

Nominal voltage Uo/U

3.6/6.6KV to 19/33KV

Frequency

50Hz

Conductor

Stranded compacted circular copper or aluminium conductors according to IEC 60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383

Conductor water blocking

All internal interstices filled with water blocking compound

Insulation

Extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1, dry cured process

Separation sheath

For armoured cable

 
Applications
  • Power supply stations
  • Indoors, cable ducts, outdoors
  • Underground, in water
  • Cable trays
  • Industries, switchboards, power stations

 

 

Performance Characteristics

 

1.Conductor is stranded compacted circular copper or aluminium, according to IEC 60228 class 2 / VDE 0276 class 2 / VDE 0295 HD 383

2.All internal interstices of the conductor are filled with water blocking compound to prevent ingress of water

3.Insulation is of extruded XLPE compound type 2XI1 according to DIN VDE 0207 part 22 and HD 620.1

4.Dry cured process with high degree of cross-linking, free from contaminants and air voids, heat resistant

5.Follows DIN VDE 0276 Part 620-622, HD 620 S1

6.Suitable for power supply stations, indoors, cable ducts, outdoors, underground, in water and on cable trays

product-630-417
product-939-579 product-594-429

 

 

Product Q&A

 

Q: What role does the conductor water-blocking structure of Three Core MV Cables play during installation and operation?

A: All internal interstices of the conductor are filled with water blocking compound to prevent ingress of water through the conductor during storage, handling, installation and operation of the cable. If the conductor is not water-blocked, moisture may penetrate longitudinally along the strand interstices to joints or terminations, causing insulation dampness.

Q: The XLPE insulation of this cable uses a dry curing process. What is the difference compared with ordinary cross-linking processes?

A: The dry curing process does not use water or steam as the heating medium during cross-linking, so the insulation layer contains no moisture or air voids, has a high degree of cross-linking, and offers more stable insulation performance. The insulation conforms to DIN VDE 0207 part 22 and HD 620.1, free from contaminants and air voids.

Q: What electrical tests are required after installation of this cable?

A: After installation, insulation resistance measurement and DC withstand voltage tests should be carried out. The test voltage is determined according to the cable rated voltage and standard requirements. For XLPE insulated cables, the space charge effect should be considered in DC withstand voltage tests, and the cable should be fully discharged after the test. The specific test items shall follow the applicable standard and the project technical specification.

 

 

 