Three Cores Cables To BS 6622

Three Cores Cables To BS 6622
Product Introduction:
Three Cores Cables to BS 6622 are three core power cables to BS 6622, with nominal voltage Uo/U ranging from 3.6/6.6KV to 19/33KV, at frequency 50Hz. They are designed for distribution of electrical power.
Send Inquiry
Description
Technical Parameters

Hebei Hualun Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of three cores cables to bs 6622 in China. If you're going to wholesale durable three cores cables to bs 6622 made in China, welcome to get quotation from our factory. All customized products are with high quality and competitive price.

 

Three Cores Cables to BS 6622 have a plain annealed copper or aluminium conductor complying with IEC 60228/BS 6360. Copper conductors shall be stranded (class 2) and aluminium conductors shall be either solid or stranded (class 2). Insulation is cross-linked polyethylene compound XLPE or EPR. For cables with a collective metallic layer or cables with a metallic layer over each individual core with additional collective metallic layers, semi-conducting inner covering and fillers shall be applied over the laid up cores. The inner covering is made of non hygroscopic material, except if the cable is to be made longitudinally watertight. The inner covering shall be extruded or lapped. They are designed for distribution of electrical power with nominal voltage 3.6/6.6KV to 19/33KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water, as well as on cable trays for industries, switchboards and power stations.

 

 
Product Parameters

Item

Parameter

Standard

BS 6622

Nominal voltage Uo/U

3.6/6.6KV to 19/33KV

Frequency

50Hz

Conductor

Plain annealed copper or aluminium complying with IEC 60228/BS 6360; copper conductors stranded (class 2), aluminium conductors solid or stranded (class 2)

Insulation

XLPE or EPR

Inner covering & fillers

For cables with a collective metallic layer or cables with a metallic layer over each individual core with additional collective metallic layers, semi-conducting inner covering and fillers applied over the laid up cores; inner covering made of non hygroscopic material, extruded or lapped

 

 
Applications
  • Power supply stations
  • Indoors, cable ducts, outdoors
  • Underground, in water
  • Cable trays
  • Industries, switchboards, power stations

 

 

 

Performance Characteristics

 

1.Conductor is plain annealed copper or aluminium, complying with IEC 60228/BS 6360

2.Copper conductors are stranded (class 2), aluminium conductors are solid or stranded (class 2)

3.Insulation is XLPE or EPR

4.For cables with metallic layers, semi-conducting inner covering and fillers are applied over the laid up cores; the inner covering is made of non hygroscopic material, extruded or lapped

5.Follows BS 6622

6.Suitable for power supply stations, indoors, cable ducts, outdoors, underground, in water and on cable trays

product-630-417
product-570-429 product-534-354

 

 

Product Q&A

 

Q: In what cases must the inner covering and fillers of Three Cores Cables to BS 6622 use non-hygroscopic material?

A: For cables with a collective metallic layer, or cables with a metallic layer over each individual core with additional collective metallic layers, the inner covering and fillers shall be made of non-hygroscopic material. If the cable is required to be longitudinally watertight, the inner covering shall also have water-blocking properties, as determined by design.

Q: What are the characteristics of the insulation of this cable under long-term high-temperature operation?

A: XLPE insulation has a long-term allowable working temperature of 90°C and low dielectric loss at high temperatures. EPR insulation has better flexibility and is suitable for installation routes requiring some bending. Both can be selected according to project requirements.

Q: How is the ampacity corrected when multiple cables of this type are laid in parallel in a cable trench?

A: When multiple cables are laid in parallel, there is a mutual heating effect between cables. The ampacity shall be multiplied by correction factors based on the number of parallel cables and the arrangement, and the ampacity data for a single cable cannot be directly applied. If necessary, maintain spacing or take ventilation measures as designed.

 

 