Aluminium Conductor Steel Reinforced

Aluminium Conductor Steel Reinforced
Product Introduction:
Aluminium conductor steel reinforced is made of a galvanized steel core surrounded by one or more layers of concentric stranded aluminum alloy 1350. It is used as bare overhead transmission cable and as primary and secondary distribution cable.
Send Inquiry
Description
Technical Parameters

Hebei Hualun Cable Co., Ltd. is one of the most reliable manufacturers and suppliers of aluminium conductor steel reinforced in China. If you're going to wholesale durable aluminium conductor steel reinforced made in China, welcome to get quotation from our factory. All customized products are with high quality and competitive price.

 

Aluminium conductor steel reinforced has a solid or concentric stranded central steel core surrounded by one or more layers of concentric stranded aluminum alloy 1350. The wire is protected from corrosion with a zinc coating. The wire or wires which form the core are made of galvanized steel, and the external layer or layers are of aluminium. The galvanized steel core normally consists of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different. By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U.T.S. can be obtained by increasing steel content, and a higher current carrying capacity by increasing aluminium content. This wire is suitable for use in all practical spans on wood poles, transmission towers, and other structures. Applications range from long, extra high voltage (EHV) transmission lines to sub-service spans at distribution or utilization voltages on private premises. The product has a long service record because of its economy, dependability, and strength to weight ratio. The combined light weight and high conductivity of aluminum with strength of the steel core enables higher tensions, less sag, and longer spans than any alternative.

 

 
Product Parameters

Item

Parameter

Conductor structure Solid or concentric stranded steel core, surrounded by one or more layers of concentric stranded aluminum alloy 1350

Conductor material

Galvanized steel wires
Outer layer material Aluminium
Core composition Normally 1, 7 or 19 wires
Steel and aluminium wire diameter Can be the same, or different
Corrosion protection Zinc coating
Strength adjustment Higher U.T.S. by increasing steel content
Ampacity adjustment

Higher current carrying capacity by increasing aluminium content

Applicable spans All practical spans on wood poles, transmission towers, and other struct
Application range Long EHV transmission lines to sub-service spans at distribution or utilization voltages on private premises

 

 

Standards

  • American & Canadian national standards: ASTM B 232/B 232M, CSA C49
  • British Standards: BS 215-2, BS EN 50182
  • German Standards: DIN 48204
  • IEC International Standards: IEC 61089 A1/S1A, A1/S2A, A1/S3A
  • Japanese Industrial Standards: JIS C 3110
  • Russian National Standard: GOST 839-80
  • French Standard: NF C 34120

 

 

Performance Characteristics

  1. Structure: galvanized steel core surrounded by one or more layers of concentric stranded aluminum alloy 1350
  2. Galvanized steel core normally consists of 1, 7 or 19 wires
  3. Steel and aluminium wire diameters can be the same or different
  4. Steel-to-aluminium ratio can be varied for different U.T.S. and current carrying capacity
  5. Combined light weight and high conductivity of aluminum with strength of the steel core enables higher tensions, less sag, and longer spans
  6. Suitable for all practical spans on wood poles, transmission towers, and other structures
  7. Applications range from long EHV transmission lines to sub-service spans at distribution or utilization voltages on private premises
  8. Zinc coating on the steel core for corrosion protection
product-400-267
product-175-130 product-173-132

 

 

Product Q&A

 

Q: What treatment should the steel core of Aluminium conductor steel reinforced undergo before use?

A: The steel core wires are galvanized steel wires, and the zinc coating on the surface is for corrosion protection. Before stranding, check whether the zinc coating is continuous and free from skip plating. If the coating is damaged, repair it before stranding to prevent the steel core from corroding first during operation.

Q: Must the diameters of the aluminium and steel wires be the same?

A: No. The diameters of steel and aluminium wires can be the same, or different. By adjusting the combination of steel and aluminium wire diameters and their relative proportions, different ultimate tensile strengths and current carrying capacities can be obtained at the same cross-section level, to suit different line design conditions.

Q: What should be noted when this conductor is used on lines with long spans or heavy ice loads?

A: The steel core carries the mechanical load, and the aluminium wires carry the current. Under long span or heavy ice load conditions, the ultimate tensile strength and sag of the conductor should be verified to confirm whether the steel core cross-section meets the line tension requirements. Stringing should be carried out at the design tension to avoid permanent elongation of the aluminium wires due to excessive tension.

 

 

Hot Tags: aluminium conductor steel reinforced, China aluminium conductor steel reinforced manufacturers, suppliers, factory